Remote Dielectric Sensing (ReDS) Assisted Diuresis in Acute Decompensated Heart Failure
a study on Heart Failure
Summary
- Eligibility
- for people ages 18 years and up (full criteria)
- Location
- at UCSF
- Dates
- study startedstudy ends around
Description
Summary
This study evaluates the use of a wearable vest capable of non-invasively measuring lung fluid content in hospitalized patients with heart failure
Official Title
Remote Dielectric Sensing Technology Guided Diuresis in Hospitalized Patients With Acute Decompensated Heart Failure
Details
Inpatient management of acute decompensated heart failure centers around the efficient relief of congestion with IV diuretics and vasoactive agents. For the majority of patients, non-invasive, clinical bedside tools such as jugular venous pressure, pulmonary auscultation and daily weights are used to estimate cardiac filling pressures and guide diuresis. However, these methods are subject to significant inter-observer variability and can be unreliable for various reasons. Furthermore, recent studies have shown that overt signs of clinical congestion correlate poorly with hemodynamic congestion assessed by invasive means. Remote Dielectric Sensing is a novel technology that enables the non-invasive assessment of lung fluid content using a wearable vest. ReDS measurements have been shown to correlate with fluid status in hospitalized HF patients and have been used to remotely monitor ambulatory HF patients for signs of pre-clinical hemodynamic congestion. In this prospective, randomized study, we will assess the utility of ReDS guided diuresis in hospitalized patients with acute decompensated heart failure. All patients will receive daily ReDS measurements, but only treating physicians in the intervention group will be able to use these values to guide treatment.
Keywords
Heart Failure; With Decompensation, Heart Failure, ReDS-Guided
Eligibility
You can join if…
Open to people ages 18 years and up
- Patients hospitalized for acute decompensated heart failure requiring treatment with intravenous diuretics and/or IV vasoactive drugs
- Patient has signed informed consent and has authorized use and disclosed health information
- Patient is at least 18 years of age
- Patient physically suitable for ReDS measurement
- GFR>25
- Initial ReDS Measurement >35%
You CAN'T join if...
- Patient characteristics excluded from approved use of ReDS system: height less than 155cm or greater than 190cm, BMI <22 or >39, chest circumference <80cm or >115cm , or flail chest
- Evidence of focal lung lesions on history, physical exam or chest x-ray, including history of pulmonary embolism, active pneumonia, or known lung nodule
- Chronic renal failure (GFR<25)
- Prior cardiac surgery within 2 months of index admission
- Patient has a ventricular assist device or has had a cardiac transplantation
- Patients in cardiogenic shock at admission requiring inotropic support
- Congenital heart malformations or intra-thoracic mass that would affect right-lung anatomy (e.g dextrocardia, lung carcinoma, or pacemaker box in the right chest)
Location
- University of California, San Francisco
accepting new patients
San Francisco California 94143 United States
Details
- Status
- accepting new patients
- Start Date
- Completion Date
- (estimated)
- Sponsor
- University of California, San Francisco
- ID
- NCT03586336
- Study Type
- Interventional
- Participants
- Expecting 100 study participants
- Last Updated
Please contact me about this study
We will not share your information with anyone other than the team in charge of this study, which might include an external sponsor. Providing your contact details does not obligate you to participate in the research.
Thank you!
The study team should get back to you in a few business days.